Console House 10 Mode Instrukcje Operacyjne Strona 47

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 136
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 46
For an energy saver module, the status shows the current temperature,
the heating and cooling setpoints, the energy saver on/off status, and
the time remaining for any timed on/off command:
Upstairs TEMP: 78
HEAT: 70 COOL: 78
Upstairs 00:00:30
ENERGY SAVER: OFF
For a temperature sensor, the status shows the current temperature and
the Low and High setpoints:
Outdoor TEMP: 85
LOW: 70 HIGH: 80
When you are finished, press the ' * ' key twice to return to the
top-level display.
IMPORTANT NOTES:
- There is a 3 minute minimum on and off time for PESMs
designed to prevent short cycling your HVAC compressor. If the
PESM has just turned the HVAC system on or off, it will wait 3
minutes before changing it, even though the display does change.
- If you change the Heat or Cool setback temperature on the
Model 1101 PESM, the system will insure that there is always at
least four degrees Fahrenheit difference between the Heat and
Cool temperatures by altering the other setback temperature as
necessary.
- PESMs are not affected by All On or All Off commands.
PESMs can also be used to report potential freeze conditions before
damage to pipes and appliances can occur. An alarm will be
generated if a temperature below 40 degrees is detected by any PESM
in the system. The alarm will not clear until the temperature exceeds
45 degrees.
Freeze Alarm
Przeglądanie stron 46
1 2 ... 42 43 44 45 46 47 48 49 50 51 52 ... 135 136

Komentarze do niniejszej Instrukcji

Brak uwag