Console House 10 Mode Instrukcje Operacyjne Strona 117

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 136
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 116
UNDERWRITER'S LABORATORIES
REQUIREMENTS
For a complete list of requirements and restrictions when installing the
Omni panel in a UL Listed system, refer to the Underwriter's
Laboratories Requirements section of the Installation Manual (10I00).
When used in UL Listed Installations, the following items apply:
1.The "High Security Mode" must be ON.
2.The "Enable Auto Bypass" feature must be OFF.
3.The ENTRY DELAY shall not exceed 45 seconds for residential
applications; 60 seconds for commercial applications.
4.The EXIT DELAY shall not exceed 60 seconds.
5.Double Delay and Quad Delay zone types shall not be used.
6.For residential applications the sounding device may be mounted
indoors. If, however, the sounding device is connected to the
"EXT HORN" terminals of the Omni, then the "OUTSIDE
SIREN DELAY" shall be set to 0.
7.The DIAL OUT DELAY shall not exceed 30 seconds.
8.The BEEP ON TROUBLE feature must be ON, and CONSOLE
SOUNDER must be ON.
Installer:
NAME: __________________________________
NUMBER: _______________________________
118 Omni Owner's Manual
Przeglądanie stron 116
1 2 ... 112 113 114 115 116 117 118 119 120 121 122 ... 135 136

Komentarze do niniejszej Instrukcji

Brak uwag