The Model 1101 PESM is used when you are have any thermostat,
other than a HAI Communicating Thermostat, and would like to
control your heating and cooling system with the Omni system. The
PESM is a temperature sensor and control relay in a small enclosure
that mounts near your central heating, ventilation, and air
conditioning (HVAC) system thermostat. The PESM allows the Omni
to read the temperature of the area that the HVAC system controls.
When you are away or asleep, the PESM can be set to allow the
temperature to drift higher or lower to reduce the operating time of the
HVAC system, hence saving energy dollars.
The PESM provides an energy saver function. When the energy saver
is on, the HVAC system is set back, meaning that the temperature is
allowed to rise or fall to an energy saving level. When the energy saver
is off, your thermostat operates normally. Your thermostat should be
set to the desired comfort temperature. Only when the energy saver is
on will the temperature be allowed to deviate from your normal
thermostat setting.
There are three temperatures associated with each Model 1101 PESM:
Temperature
- this is the air temperature read by the PESM.
Heat temperature
- the air temperature will be allowed to fall to this
temperature when the energy saver is on.
Cool temperature
- the air temperature will be allowed to rise to this
temperature when the energy saver is on.
The following control actions are allowed on PESMs:
Turn Energy Saver On and Off
Turn Energy Saver On and Off for a specified time
Set heating setpoint
Set cooling setpoint
You can turn the energy saver on, off, use a timed on/off, and change
the Heat and Cool temperatures from the console or by telephone.
Commands can also be programmed so that they occur by time
schedule or by event, such as security mode change. For example, the
system can be set up to turn the energy saver(s) On and make the Heat
Programmable
Energy Saver
Modules (PESMs)