7. Press the ' * ' twice to return to the top-level display. Have a
partner open each door and window, then close it. The display
should show the zone name as being "NOT RDY" and then return
to "SYSTEM OK."
8. Trip all motion detectors; the same should happen.
9. Notify your Central Station that you intend to test the system. To
test the interior sounder and exterior siren, press the 1 and 3 keys
simultaneously. Press the OFF key and your Code within 5
seconds to prevent the system from dialing out. You should have
heard both sirens activate.
10. Test your smoke detectors as recommended by the manufacturer.
Be ready to silence the alarm system as soon as it sounds.
11. Pick up an inside phone and press the # key. When the menu is
spoken, press 8, then 3. The Omni should say "ADDRESS IS:"
and play your name and address. If it does, the telephone dialer,
telephone access and telephone control systems are all working
correctly.
12. Turn on, then off each lamp or appliance module used in the
When Alarm macro and Flash For Alarm purposes.
13. If you wish to test your system's link to your Central Station
monitoring service, call them first and inform them that you will
be testing your alarm system. Set off the alarm, allowing
sufficient time for any dial out delays that you may have, then turn
the alarm system Off. The Central Station should receive the
alarm code.
14. Test is complete. Be sure that you have restored any bypassed
zones.
Your Omni controller and the consoles are designed to require very
little maintenance.